UNIVERSITY BASKETBALL GYMNASIUM LIGHTING
CPS Lighting designs and supplies sports lighting systems. The Jiaxing University indoor basketball gymnasium project account describes a customised lighting solution using TLX Series sports lamps. Its brief combines university teaching and athlete training with formal basketball competitions and television coverage.
The source identifies a Grade IV competition and TV broadcast objective. It includes project photographs and a false-colour lighting simulation, but no complete numerical acceptance report. This case therefore explains the documented scope and design approach without presenting unverified illuminance or energy savings as measured results.
Share your court plan and mounting details. The simulation depends on those inputs; the installed result requires site verification.
Basketball
University teaching, training and matches
TLX Series
Product family identified in the source
Grade IV
Competition and TV broadcast brief
1. A campus hall with competition ambitions
The university’s stated need was a basketball environment serving several operating conditions: sports lessons, routine training, campus events and regional competitions. The original account describes uneven brightness, distracting glare and unstable light output in the previous installation, with limitations for televised events.
The proposed upgrade focused on useful court coverage, player comfort and stable output. Exact court dimensions, fixture quantity, installed wattage and control settings are not documented. These omissions matter when assessing the equipment schedule, electrical load and the performance of each operating scene.
| Project item | Documented information |
|---|---|
| Venue | Jiaxing University indoor basketball gymnasium |
| Main use | Teaching, athlete training and formal basketball matches |
| Source product family | TLX Series professional sports lamps |
| Lighting brief | Grade IV competition and TV coverage objective |
| Quantity and rated power | Not established by the supplied material |
| Available design evidence | False-colour simulation image and project photographs |
2. Review player sightlines alongside camera needs
The photographs show lighting rows beneath steel roof members and building services, surrounding a basketball court and spectator stands. They help illustrate the installation environment without defining the full aiming schedule or exact mounting height. None is treated here as a controlled before-and-after measurement.
For a comparable basketball hall, check the upward view during shooting and rebounding, direct views of bright fixtures and reflections from the playing surface. A television brief also requires attention to light on players from the intended camera directions. A bright floor alone does not establish suitable camera-facing illumination.
The supplied false-colour graphic has a scale from 1 to 1600 lx. That legend is a visualisation scale, not a measured average, minimum or uniformity result. Without the model inputs, calculation grid and accompanying report, numerical performance should not be inferred from the colours. A final design should use actual geometry, obstructions and luminaire photometric files.
3. Agree the acceptance evidence for each scene
The old article states full Grade IV compliance and suitability for television coverage. It does not supply a signed test report, numerical horizontal or vertical illuminance, uniformity ratios, glare assessment or camera-specific flicker results. The classification is retained as the project brief, rather than independent confirmation of complete compliance.
Before a similar project proceeds, agree the playing activities, camera positions, operating scenes and measurement method. After installation, verify aiming and measure the agreed grids under those scenes. If broadcast or slow-motion use is required, assess the selected camera settings as well as the lighting system.
No defensible rated-power total or saving percentage can be calculated because the luminaire quantity and power schedule are absent. Comparable old and new circuit measurements, ballast details, operating hours and controls would be needed for an energy assessment.
4. CPS lighting solution and supply support
The source attributes a customised sports lighting solution and TLX Series selection to CPS. It does not establish every contractor’s installation and commissioning responsibilities. For a new venue, clarify design inputs, electrical and mounting interfaces, aiming guidance and acceptance deliverables before ordering.
CPS’s OEM/ODM capabilities include metal processing, finishing and assembly. Its testing laboratory lists electrical, photometric and environmental equipment. These are published company capabilities, rather than proof that every historical installation passed a particular test.
5. Historical TLX family and a current catalogue reference
Source configuration: TLX Series sports lamps. A complete model code, wattage, quantity, beam selection and driver specification require the historical supply documents. The current product below is shown separately for new-project discussion.
Dubhe Projection Light — 200 W
Current reference only; not identified as the historical TLX supply.
| Catalogue item | Published reference |
|---|---|
| Rated power | 200 W |
| Luminous flux | 30,000 lm |
| Colour temperature | 5700 K |
| Colour rendering | Ra ≥ 80 |
| Listed beam angle | 45° |
| Ingress protection | IP66 |
These catalogue values do not describe the historical site result or establish a direct replacement. Optics and mounting geometry must be assessed against the new project’s agreed criteria.
6. Plan your basketball gymnasium upgrade
Send a court plan, building dimensions, mounting heights and positions, photographs and intended playing levels. Include television or camera requirements, operating scenes and installation access. For a retrofit energy comparison, provide the existing lamp schedule, controls and electricity records.
Share your court plan and mounting details. The simulation depends on those inputs; the installed result requires site verification.