One coordinated pole system for lighting and connected venue services
CPS Lighting supplies customized integrated smart pole solutions. For the 19th Hangzhou Asian Games, its project record describes 400 poles around the Hangzhou Olympic Sports Center venue cluster, bringing lighting and connected equipment into a coordinated streetscape.
For venue owners, contractors and municipal buyers, the useful question is not how many devices can fit on a pole. It is which services your site needs, how they connect and who maintains them. This case shows CPS’s approach to that integration.

400 poles
Reported project deployment
Quantity recorded in the CPS case.
5 groups
Integrated function categories
Grouped in the original configuration summary.
Custom design
Architecture-led pole appearance
Lotus and cloud motifs described by CPS.
1. The venue and the infrastructure brief
The project concerns outdoor supporting infrastructure around the Asian Games venues, rather than a single competition court. Pedestrian routes, entrances and plazas need lighting, while the operator also needs surveillance, public information and communication services.
CPS describes a pole design incorporating West Lake lotus and cloud elements to complement the surrounding architecture. The supplied photographs show the poles in use beside venue entrances and open public spaces, giving buyers a clearer reference than a generic catalogue rendering.
2. What the project record establishes
The figures below describe this project, not a standard package for every customer. The original configuration image groups the functions into five categories. It does not provide a complete device schedule for each of the 400 poles.
| Project item | Published record | Meaning for a new enquiry |
|---|---|---|
| Deployment scale | 400 integrated poles | Confirm your own site quantity and locations. |
| Function categories | 5 groups in the source table | Choose modules by zone, not by a fixed bundle. |
| Luminaire wattage / pole height | Not specified | Request a model and structural schedule. |
| Measured energy-saving percentage | Not published | Compare metered operation against a baseline. |
On smaller screens, swipe the table to see all columns.
A venue support pole should not be described as broadcast-certified simply because it stands near an international competition. This case therefore focuses on the documented smart pole installation, without treating a generic sports-lighting grade chart as proof of its lighting performance.
3. The integrated pole and its functions
The supplied system is a customized multifunctional smart pole, not an identified off-the-shelf stadium floodlight. Its source configuration describes the following modules; the actual mix at each location should be confirmed in the equipment schedule.

| Function group | Source configuration | What the buyer should clarify |
|---|---|---|
| Smart LED lighting | Remote switching, dimming and status monitoring | Optics, light levels, control interface and operating scenes. |
| Security monitoring | Video surveillance | Coverage, recording, access permissions and ownership. |
| Public services | Wi-Fi, broadcasting and information display | Network access, content control and service coverage. |
| Environmental monitoring | Temperature, humidity and wind data | Sensor locations, calibration and required accuracy. |
| Emergency support | Emergency calls and radar sensing | Response routing and integration with the operator. |
On smaller screens, swipe the table to see all columns.
The pole shares a physical support, but the services still have different power, network and maintenance needs. Adding a display or sensor changes the equipment load and wind exposure. Agree the complete module list before confirming pole structure, foundations and access arrangements.
4. Remote control and daily operation
The CPS account describes IoT connectivity and a cloud management platform for remote lighting control and equipment status. Internet of Things (IoT) means connecting devices so their data and commands can be exchanged; it does not automatically make every third-party device compatible.

For a new project, agree device interfaces, account permissions and data ownership before procurement. Test scheduled lighting scenes, fault notifications and what happens when communication is lost. Lighting availability and emergency response should not depend on an untested dashboard.
Dimming can reduce lighting electricity use during quieter periods, but displays, cameras and network equipment may remain active. Compare whole-system metered energy, not just lamp wattage. The source provides no measured saving percentage, so none is claimed here.
5. What CPS can bring to your project
This case demonstrates CPS’s experience coordinating pole appearance, lighting and connected services for a large venue setting. The Hangzhou smart pole project video page provides a further CPS project reference. The company profile explains its lighting design and manufacturing background.

For your proposal, discuss OEM/ODM customization and request relevant product test records through CPS’s testing laboratory. The quote should separate equipment supply, platform integration, installation responsibilities and ongoing support rather than leave “turnkey” undefined.
Shared infrastructure also needs maintenance access and room for future changes. ITU’s multi-service infrastructure guidance discusses these planning issues; it is background guidance, not a certification held by this project. Review public-network and camera data requirements separately.
6. Request a site-specific smart pole proposal
Planning smart pole lighting for a sports complex, campus or municipal space? Send CPS a site plan, intended pole locations, architectural references, required modules and information about the existing power and communication network.
Request a customized equipment proposal and scope of supply. CPS also offers free DIALux lighting simulation for the lighting component; surveillance coverage, network capacity and platform integration need their own review. For lighting-only requirements, see the LED lighting product range.
Email: info-cps@cps-lighting.com